Impulse Application Note : Preplaced_IP method
Table of Contents
Â
Document History
Revision | Date | Modification |
1.0.0 | 29/04/2022 | Initial Document |
Related documentation
Reference | Description | Version |
RD1 | NanoXplore_Nxmap_User_Manual_v3.0.5 | V3.0.5 |
RD2 | training package | Â |
RD3 | training package user manual |
Summary
This document describes how to instantiate an IP into a TOP design with NXMAP flow.
Introduction
After compiling a design into NXMAP, it’s possible to instantiate this compiled design as an IP into a top design. Nxmap could use the placement of the compiled IP into an other design.
How to use preplaced IP
An example is provided in the training package environment. Please refer to RD3.
The preplaced IP testcase is stored to the path below
cd $WORKDIR/trainingpackage/test/PlacingConstraint/Preplace |
Please launch the following commands
nxpython nxmap_script.py --argument Preplace |
The command compiles the switch_counter design that it is used as an IP and a top level design, the switch design, that instantiates the switch counter.
The aperture of the IP has to be smaller than possible.
To add the preplaced IP into the design, add the line below into constraints file (project_constraints.py)
p.addBlackBox('switch_counter(*)', 'IP', '../switch_counter_preplaced_NG-MEDIUM.nym', 'g_inst.i_switch_counter_0:2x6') |
switch_counter(*) : VHDL entity name
IP : parameter to indicate that is an IP
switch_counter_preplaced_NG-MEDIUM.nym : it is the file of the IP placement (placed-auto.nym) generated by Nxmap. In the example, it is copied to switch_counter_preplaced_NG-MEDIUM.nym into the workdir of the TOP level design in which the IP is preplaced
g_inst.i_switch_counter_0:2x6 : instantiated name of the IP and the coordinate of the anchor (column 2 x row 6). Please check that the anchor of the preplaced IP is instantiated correctly, it means that the placement is used the same kind of ressources.
The preplaced IP could be instantiate several times.
p.addBlackBox('switch_counter(*)', 'IP', '../switch_counter_preplaced_NG-MEDIUM.nym', 'g_inst.i_switch_counter_0:2x6;g_inst.i_switch_counter_1:3x6') |
The code source of the preplaced IP has to be removed from the project (project_files.py).
def add_files(p,sources_files_directory,variant,argument): |
Note:
It’s allowed to superpose preplaced IP but the ressources have to be sufficient to avoid placement problems or routing problems
Several instances are not supported yet: CDC, CKS, FIFO, XFIFO, CSC, GCK, PLL, WFG, SOC interface, HSSL
IOB and BFR are converted into buffer
The constraintPath is not used with elements into preplaced IP, please make sure that the preplaced IP is optimally constrained
© NanoXplore 2022