Parameter name | Allowed values | Comments |
|
|
|
Entity name | Any user’s name (VHDL compliant) | Note that NXcore allows to define independent names for the entity and the VHDL file. The VHDL file name can be defined |
Input line count | Range 2 to 240 | Memory width (same as NXscope) |
Capture_depth | 2K, 4K, 6K, 12K, 24K or 48K | Memory depth (same as NXscope) |
Pre-trigger samples | 1 to 1000 | Can be used to store some samples before the NXscope_Startup condition is met. Make sure the capture clock is available during the specified amount of Pre-trigger samples to get the correct behavior. |
Trigger line count | 1 to 4 | Allows 1 to 4-bit trigger condition |
Trigger value | ‘0’ or ‘1’ can be defined for each trigger input line | Value to be detected for trigger. Ex for 4 Trigger line count : “0110”. Only ‘0’ and ‘1’ values are supported. |