Table of Contents | ||||
---|---|---|---|---|
|
Copyright
All the contents of this document are protected by the copyright law. They may not be disclosed to third parties or copied or duplicated in any form without consent of NanoXplore.
Introduction
Aim of document
This document is intended to guide users on NXmap Impulse software best practice.
The aim is to ease NXmap Impulse using and get the best recommendations in order to implement a project into NanoXplore components.
For any kind of helpassistance, please contact NanoXplore support team at support@nanoxplore.com.
Content
All recommendations are divided in several categories depending on product development phase.
They are based mainly on NXpython methods but some of them can be applied in the GUI.
Design
NanoXplore primitive instantiation
All NanoXplore primitives are listed in nxLibrary-<variant_name>.vhdp available in the release archive. A documentation is also available in order to get information about all generics and io in https://nanoxplore-wiki.atlassian.net/wiki/spaces/SANDBOX/pages/202244165 Impulse 23.3 Library Guide .
It is recommended to only add the nxpackage in the work library and not component declarations as they are already declared in the package.
Clock management
NanoXplore FPGAs contain a low-skew network in order to spread signal with high fanout like clock, reset , and load signals.
The user must be very careful about the way to spread clock through the design. It is advised to follow the following rules sorted by level of recommendation:
Use a pad directly connected to the closest CKG (these pads are suffixed by _CLK). Either the user instantiates a PLL or a WFG in the design or the tool instantiates automatically a WFG in bypass mode.
MEDIUM/LARGE: Use a common pad or internal logic and use a buffer NX_BD in global_lowskew mode.
ULTRA: Use a common pad or internal logic and use a NX_GCK_U in Common to System Converter CSC mode.
Please have a look at Impulse 23.3 Training Package : Application Note Design/LowskewManagement project.
Reset management
Like clocks, reset are generally spread to the whole design through the low-skew network because of high fanout too.
Reset can be asynchronous or synchronous as registers of NanoXplore FPGAs are compliant with both.
Global signals management
There are some signals with high fan out can be mapped into low-skew network and introduced some important delays. It could be the problem with synchronous signals load, set, reset, …
In order to avoid this problem, use rejectLowskew method.
Code Block | ||
---|---|---|
| ||
p.rejectLowskew('inst1|reset_sync') |
Memory initialization
There are several ways to initialize a memory (attribute, generic, python method).
It is recommended to rather use python method addMemoryInitialization described in /wiki/spaces/~814749387/pages/48660481 as it is compliant with inferred and instantiated memories.
Please have a look at Training Package Application Note Init/Ram project.
Memory Inference
In order to infer a memory instead of instantiating a NanoXplore primitive (advantage is the user can choose with the same RTL code to map this memory in RF, RAM, RAM_ECC, … thanks to NXpython constraints), it is recommended to follow TrainingPackage Design/MemInfer examples providing inference for ROM, SRAM, DPRAM with and without ECC.
Please have a look at Training Package Application Note Design/MemInfer project.
Hierarchy
It is recommended to divide the design in well sized modules depending on the function they are responsible for.
It will be very helpful to constrain the design by module then.
Logic depth
It is highly recommended to avoid large logic depth between registers as it will limit the maximum frequency of the design.
In addition, when a LUT is used, the DFF from the same Functionnal Element will be used either as a register or a buffer so adding pipeline in the design won’t consume any additional instance.
Project creation
NXmap is based on Python scripts that is to say a project is a class and all options and constraints are methods associated to this class.
The user can either create a project based on a NanoXplore template (recommended) or start it from scratch.
In case of NanoXplore template, please ask NanoXplore support team at support@nanoxplore.com.
In case of starting from scratch, it can be easier to create a project using the GUI in order to get the right basic NXpython methods.
The project needs the following database:
Top cell library and top cell name
All files added to associated library
Options and constraints
Note |
---|
Never add a nxLibrary file to your project. NXmap tool already get the needed files with NX primitives. |
Whatever the project base, it is recommended to comply with the following rules:
Set options before any progress.
Set IO pads locations and parameters before any progress.
Save your project after each progress step.
Separate your project in categories (setup,synthesis, placing, routing, sta) and set your constraints at the right place.
Project check
Once the project is launched, it is necessary to check logs and reports in order to be sure there is not any issue leading to errors, undesired optimizations, …
Logs and report files analysis
Errors and warnings
First of all, check the project is successful until the required progress step.
If not, a message appears in the console. Sometimes, the message is clear enough, but it could not be. So errors.rpt and warning.rpt reports can be very useful in order to grab the issue.
Note there reports are generated only if there are messages to report to the user.
If reported messages are not clear enough to solve the issue, contact the NanoXplore support team at support@nanoxplore.com giving the CONTEXT code and an archive in order to reproduce the issue (RTL sources + scripts).
Even though the project is successful, it is advised to parse these files.
Complexity
After errors and warnings are solved or understood, check hierarchy.rpt and progress.rpt in order to check the number of instances is relevant with the estimation.
In order to get complexity module by module without confining it in a region, it is possible to use addModule method described in /wiki/spaces/~814749387/pages/48660481.
Refer to #Floor_planning_Complexity for more details.
IO Location
Check in progress.rpt none IO has been automatically placed by the design. It is marked with an exclamation sign.
Common Errors
There are typical types of errors :
Oversize : Not enough instance capacity in the area
Overflow : Not enough routing capacity in the area
Blending Tile : Unable to route a path
These errors can be solved by changing the following parameters/options :
If modules are constrained with constrainModule method, increase area size
Change the Seed used for P&R
Change the following options: CongestionEffort, DensityEffort, RoutingEffort
STA
Once the project is mature enough, Static Timing Analysis can be done in order to check how fast the design can operates.
STA tool can be launched from any step after Preparing (Placing 1/5) with the following example method:
Code Block |
---|
Timing_analysis = p.createAnalyzer()
Timing_analysis.launch({'conditions': 'typical', 'maximumSlack': 500, 'searchPathsLimit': 10}) |
It is advised to launch a STA after Preparing as it shows up most critical paths and the maximum frequency with most optimistic hypothesis. If maximum frequencies are not higher enough at this step, it won’t be after routing for sure.
Clock creation
The input clock frequencies and other parameters must be informed to NXmap for STA.
Please refer to createClock and createGeneratedClock described in /wiki/spaces/~814749387/pages/48660481.
If a PLL is used, PLL output clock frequencies are automatically computed by the software.
Special path and clock domains relationship
Declare all false paths and multi cycle paths in order to not take into account some paths between registers in some particular cases.
Please refer to addFalsePath and addMultiCyclePath in /wiki/spaces/~814749387/pages/48660481.
Clock groups can be created if clock domains are completely unrelated.
Timing files analysis
When launching the STA tool, the following files are created :
Summary_<progress_step>_<conditions>.timing
Violation_<progress_step>_<conditions>.timing
Timing_Constraints_Report_<progress_step>_<conditions>.timing
DOMAIN_Input_to_<clk>_<progress_step>_<conditions>.timing
DOMAIN_<clk1>_to_<clk2>_<progress_step>_<conditions>.timing
DOMAIN_<clk>_to_Output_<progress_step>_<conditions>.timing
Use the first 3 timing files in order to get an overview of the project and other ones to analyze paths.
Optimization
Mapping
Operator
Operators are divided in 3 categories :
Adder (ADD)
LessThan (LTN)
Multiplier (MUL)
LessThan, LessThanOrEqual, GreaterThan and GreaterThanOrEqual are all considered as LessThan operators.
It is possible to map this operators in LUT, Carry or DSP thanks to addMappingDirective method described in /wiki/spaces/~814749387/pages/48660481.
By default, adders are mapped into Carry and Multipliers in DSP. But it can sometimes be interesting to change default mapping directives.
Check #Mapping_Directive_Operator for information about constraint setting.
Memory
Memories can be mapped into logic elements (LUT/DFF), register files (RF), Memory Blocks (RAM) or Memory Blocks protected by EDAC correction thanks to addMappingDirective method described in /wiki/spaces/~814749387/pages/48660481.
By default, small memories (equal or less than 64x16) will be mapped into RF and bigger mapped into RAM. But it can sometimes be interesting to change default mapping directives.
It it highly recommended to size the design according to available depths and heights. Otherwise, too many memories will be instantiated and will affect the routing and STA performances.
In case of memory with reset assertion, the memory has to be mapped into DFF as RF or RAM does not have a reset input pin.
Check #Mapping_Directive_Memory for information about constraint setting.
Placing
In order to improve the maximum clock frequency for each clock domain, it is advised to follow the following steps:
Define a floor plan for the design depending on module relationships and pinout.
Apply the floor plan to your NXmap project using confineModule described in /wiki/spaces/~814749387/pages/48660481. Check #Floor_planning_Constrain_module for information about constraint setting.
If needed, repeat this process going deeper and deeper in the design hierarchy.
For last most critical paths, use constrainPath described in /wiki/spaces/~814749387/pages/48660481in order to create a region with only a few elements contained into the specified path. Check #Floor_planning_Constrain_path_between_registers for information about constraint setting.
It can also have a very positive impact to create unitary projects and reuse the routed projects as a blackbox in your final top project using addBlackBox described in /wiki/spaces/~814749387/pages/48660481.
It is also possible to place manually instances in a specified spot thanks to the following NXpython methods all described in /wiki/spaces/~814749387/pages/48660481:
addPLLLocation for PLL instance in a CKG. Check #Instance_placing_Ring_placing for information about constraint setting.
addWFGLocation for WFG instance in a CKG and a WFG spot. Check #Instance_placing_Ring_placing for information about constraint setting.
addRAMLocation for RAM instance in a CGB. Check #Instance_placing_Ram_placing for information about constraint setting.
addDSPLocation for DSP instance in a CGB and a DSP spot. Check #Instance_placing_Dsp_placing for information about constraint setting.
setSite for LUT/DFF/CY in a TILE. Check #Instance_placing_Tile_placing for information about constraint setting.
...
The logic depth of a design must be controlled. the method reportDesignComplexity is very helpful to have an overview.
It
Please have a look at NxBeta_NXpython specification reportDesignComplexity method.
...
Info |
---|
PLL outputs are connected to WFG of the same CKG. User can either instantiate a WFG or let the tool instantiate a WFG in bypass mode. WFG outputs are connected to the low-skew network. |
Note |
---|
Do not use NX_BD(global_lowskew) or NX_GCK(CSC) with connected input already in low-skew network. |
In case of clock gating or clock mux, it is recommended to implement the following architecture:
Clock Gating:
MEDIUM/LARGE: Use a NX_CKS to gate a clock system signals with a command common signal.
ULTRA: Use a NX_GCK_U in Clock Switch CKS mode to gate a clock system signals with a command common signal.
Clock MUX:
ULTRA: Use a NX_GCK_U in Clock MUX MUX mode to switch between 2 clock system signals with a command common signal.
Please have a look at Impulse 23.3 Training Package : Application Note Component/ClockSwitch project.
Note |
---|
It is highly recommended to not cascade GCK as it is not natively supported by the architecture. User can cascade GCK anyway by allowing the associated option leading to a longer clock insertion path. |
Reset management
Like clocks, reset are generally spread to the whole design through the low-skew network because of high fanout too.
Reset can be asynchronous or synchronous as registers of NanoXplore FPGAs are compliant with both.
Global signals management
There are some signals with high fanout can be mapped into low-skew network and introduced some important delays. It could be the problem with synchronous signals load, set, reset, …
In order to avoid this issue, use rejectLowskew method.
Code Block | ||
---|---|---|
| ||
p.rejectLowskew('inst1|reset_sync') |
Memory initialization
There are several ways to initialize a memory (attribute, generic, python method).
It is recommended to rather use python method addMemoryInitialization described in Impulse 23.3 NxPython Specification as it is compliant with inferred and instantiated memories.
Please have a look at Impulse 23.3 Training Package : Application Note Init/Ram project.
Memory Inference
In order to infer a memory instead of instantiating a NanoXplore primitive (advantage is the user can choose with the same RTL code to map this memory in RF, RAM, RAM_ECC, … thanks to NXpython constraints), it is recommended to follow TrainingPackage Design/MemInfer examples providing inference for ROM, SRAM, DPRAM with and without ECC.
Please have a look at Impulse 23.3 Training Package : Application Note Design/MemInfer project.
Hierarchy
It is recommended to divide the design in well sized modules depending on the function they are responsible for.
It will be very helpful to constrain the design by module then.
Logic depth
It is highly recommended to avoid large logic depth between registers as it will limit the maximum frequency of the design.
In addition, when a LUT is used, the DFF from the same Functionnal Element will be used either as a register or a buffer so adding pipeline in the design will not consume any additional instance.
Project creation
Impulse is based on Python scripts that is to consider a project as a class and all options and constraints are methods associated to this class.
The user can either create a project based on a NanoXplore template (recommended) or start it from scratch.
To use a NanoXplore template, please ask NanoXplore support team at support@nanoxplore.com.
In case of starting from scratch, it can be easier to create a project using the GUI in order to get the right basic NXpython methods.
The project needs the following database:
Top cell library and top cell name
All files added to associated library
Options and constraints
Note |
---|
Never add a nxLibrary file to your project. Impulse tool already get the needed files with NX primitives. |
Whatever the project base, it is recommended to comply with the following rules:
Set options before any progress.
Set IO pads locations and parameters before any progress.
Save your project after each progress step.
Separate your project in categories (setup,synthesis, placing, routing, sta) and set your constraints at the right place.
Project check
Once the project is launched, it is necessary to check logs and reports in order to be sure there is not any issue leading to errors, undesired optimizations, …
Logs and report files analysis
Errors and warnings
First of all, check the project is successful until the required progress step.
If not, a message appears in the console. Sometimes, the message is clear enough, but it could not be. So errors.rpt and warning.rpt reports can be very useful in order to grab the issue.
Note there reports are generated only if there are messages to report to the user.
If reported messages are not clear enough to solve the issue, contact the NanoXplore support team at support@nanoxplore.com giving the archive in order to reproduce the issue (RTL sources + scripts).
Even though the project is successful, it is advised to parse these files.
Complexity
After errors and warnings are solved or understood, check hierarchy.rpt and progress.rpt in order to check the number of instances if it is relevant with the estimation.
In order to get complexity module by module without confining it in a region, it is possible to use addModule method described in Impulse 23.3 NxPython Specification.
Refer to #Floor_planning_Complexity for more details.
IO Location
Check in progress.rpt none IO has been automatically placed by the design. It is marked with an exclamation sign.
Common Errors
There are typical types of errors :
Oversize : Not enough instance capacity in the area
Overflow : Not enough routing capacity in the area
Blending Tile : Unable to route a path
These errors can be solved by changing the following parameters/options :
If modules are constrained with constrainModule method, increase area size
Change the Seed used for P&R
Change the following options: CongestionEffort, DensityEffort, RoutingEffort
STA
Once the project is mature enough, Static Timing Analysis can be done in order to check how fast the design can operate.
STA tool can be launched from any step after Preparing (Placing 1/5) with the following example method:
Code Block |
---|
Timing_analysis = p.createAnalyzer()
Timing_analysis.launch({'conditions': 'typical', 'maximumSlack': 500, 'searchPathsLimit': 10}) |
It is advised to launch a STA after Preparing as it shows up most critical paths and the maximum frequency with most optimistic hypothesis. If maximum frequencies are not higher enough at this step, the value will be less after routing.
Clock creation
The input clock frequencies and other parameters must be informed to Impulse for STA.
Please refer to createClock and createGeneratedClock described in Impulse 23.3 NxPython Specification .
If a PLL is used, PLL output clock frequencies are automatically computed by the software.
Special path and clock domains relationship
Declare all false paths and multi cycle paths in order to not take into account some paths between registers in some particular cases.
Please refer to addFalsePath and addMultiCyclePath in Impulse 23.3 NxPython Specification .
Clock groups can be created if clock domains are completely unrelated.
Timing files analysis
When launching the STA tool, the following files are created :
Summary_<progress_step>_<conditions>.timing
Violation_<progress_step>_<conditions>.timing
Timing_Constraints_Report_<progress_step>_<conditions>.timing
DOMAIN_Input_to_<clk>_<progress_step>_<conditions>.timing
DOMAIN_<clk1>_to_<clk2>_<progress_step>_<conditions>.timing
DOMAIN_<clk>_to_Output_<progress_step>_<conditions>.timing
Use the first 3 timing files in order to get an overview of the project and other ones to analyze paths.
Optimization
Mapping
Operator
Operators are divided in 3 categories :
Adder (ADD)
LessThan (LTN)
Multiplier (MUL)
LessThan, LessThanOrEqual, GreaterThan and GreaterThanOrEqual are all considered as LessThan operators.
It is possible to map this operators in LUT, Carry or DSP using addMappingDirective method described in Impulse 23.3 NxPython Specification .
By default, adders are mapped into Carry and Multipliers in DSP. But it can sometimes be interesting to modify default mapping directives.
Check #Mapping_Directive_Operator for information about constraint setting.
Memory
Memories can be mapped into logic elements (LUT/DFF), register files (RF), Memory Blocks (RAM) or Memory Blocks protected by EDAC correction using addMappingDirective method described in Impulse 23.3 NxPython Specification .
By default, small memories (equal or less than 64x16) will be mapped into RF and bigger ones mapped into RAM. But it can sometimes be interesting to modify default mapping directives.
It is highly recommended to size the design according to available depths and heights. Otherwise, too many memories will be instantiated and will affect the routing and STA performances.
In case of memory with reset assertion, the memory has to be mapped into DFF as RF or RAM does not have a reset input pin.
Check #Mapping_Directive_Memory for information about constraint setting.
Placing
In order to improve the maximum clock frequency for each clock domain, it is advised to follow the following steps:
Define a floorplan for the design depending on module relationships and pinout.
Apply the floorplan to your Impulse project using confineModule described in Impulse 23.3 NxPython Specification . Check #Floor_planning_Constrain_module for information about constraint setting.
If needed, repeat this process going deeper and deeper in the design hierarchy.
For last most critical paths, use constrainPath described in Impulse 23.3 NxPython Specification in order to create a region with only a few elements contained into the specified path. Check #Floor_planning_Constrain_path_between_registers for information about constraint setting.
It can also have a very positive impact to create unitary projects and reuse the routed projects as a blackbox in your final top project using addBlackBox described in Impulse 23.3 NxPython Specification .
It is also possible to place manually instances in a specified using the following NXpython methods all described in Impulse 23.3 NxPython Specification :
addPLLLocation for PLL instance in a CKG. Check #Instance_placing_Ring_placing for information about constraint setting.
addWFGLocation for WFG instance in a CKG and a WFG spot. Check #Instance_placing_Ring_placing for information about constraint setting.
addRAMLocation for RAM instance in a CGB. Check #Instance_placing_Ram_placing for information about constraint setting.
addDSPLocation for DSP instance in a CGB and a DSP spot. Check #Instance_placing_Dsp_placing for information about constraint setting.
setSite for LUT/DFF/CY in a TILE. Check #Instance_placing_Tile_placing for information about constraint setting.
Anchor | ||||
---|---|---|---|---|
|
The logic depth of a design must be controlled. the method reportDesignComplexity and reportHierarchyComplexity are very helpful to have an overview.
Please have a look at Impulse 23.3 NxPython Specification reportDesignComplexity and reportHierarchyComplexity methods.
Anchor | ||||
---|---|---|---|---|
|
In order to get complexity for each module of the design, check the detailed hierarchy of the design.
Complexity is given for each module with the sum of the complexity of each sub-module and the module itself.
For instance:
Code Block | ||
---|---|---|
| ||
08:50:49:info | --------------------------------------------
08:50:49:info | - Detailed Hierarchy Statistics -
08:50:49:info | --------------------------------------------
08:50:49:info | ~ hierarchical
08:50:49:info | Resources:
08:50:49:info | NX_LUT : 13
08:50:49:info | NX_DFF : 73
08:50:49:info | NX_IOB : 51
08:50:49:info | NX_BFR : 99
08:50:49:info | NX_WFG : 3
08:50:49:info | ~ |-> row_col_pipe(X212B9C19) [ GEN_HIER0 ]
08:50:49:info | |-> Resources:
08:50:49:info | |-> NX_LUT : 3
08:50:49:info | |-> NX_DFF : 23
08:50:49:info | GEN_HIER0_ROW-0 | |-> timing_pipe(X2A98C8C6) [ GEN_HIER0|GEN_ROW[0].ROW_PIPE ]
08:50:49:info | | |-> Resources:
08:50:49:info | | |-> NX_DFF : 5
08:50:49:info | ~ | |-> timing_pipe(X2A98C8C6) [ GEN_HIER0|GEN_ROW[1].ROW_PIPE ]
08:50:49:info | | |-> Resources:
08:50:49:info | | |-> NX_DFF : 5 |
How to use NXpython constraints methods
Mapping directive
Anchor | ||||
---|---|---|---|---|
|
In order to map an operator into LUT, CY or DSP, follow the following steps:
Launch your design for the first time without constraint.
Grab the operator model or instance in operators.rpt report. For instance, “ | Operator 'add_3u_3u' | : add_L25 (line 25 in …”, model name is “add_3u_3u” and instance name is “add_L25”.
Add the constraint specifying instance to map the operator, for instance “ p.addMappingDirective('getModels(add_3u_3u)','ADD','DSP')” or p.addMappingDirective('getInstances(add_L25)','ADD','DSP')”, and relaunch the project.
Check in operators.rpt report the constraint matched with the desired instance.
Please have a look at Impulse 23.3 Training Package : Application Note MappingDirective/Operator project.
Anchor | ||||
---|---|---|---|---|
|
In order to map an operator into FE, RF, RAM or RAM_ECC, follow the following steps:
Launch your design for the first time without constraint.
Grab the memory model in memories.rpt report. For instance, “ | Ram 'RAM_s_mem' Analysis:”, model name is “RAM_s_mem”.
Add the constraint specifying instance to map the operator, for instance “ p.addMappingDirective('getModels(RAM_s_mem)','RAM','RAM_ECC')”, and relaunch the project.
Check in memories.rpt report the constraint matched with the desired instance.
Please have a look at Impulse 23.3 Training Package : Application Note MappingDirective/Memory project.
Instance placing
Anchor | ||||
---|---|---|---|---|
|
In order to place manually an inferred DSP in a CGB spot, follow the following steps:
...
Info |
---|
In case of direct primitive instance of the DSP, DSP name is the path to the DSP. For instance, p.addDSPLocation('module0|submodule1|DSP_INST_0','CGB[28x4]:L'). |
Please have a look at at Impulse 23.3 Training Package : Application Note PlacingConstraint/DspLocation project.
Anchor | ||||
---|---|---|---|---|
|
In order to place manually an inferred RAM in a CGB spot, follow the following steps:
Launch your design for the first time without constraint.
Grab the RAM name in memories.rpt report. For instance,“ | RAM Generation for g_loop[0].i_RAM_example|s_mem”, name is “g_loop[0].i_RAM_example|s_mem|ram0_0_0_0”.Add the constraint specifying RAM spot (CGB coordinates), for instance “p.addRAMLocation('g_loop[0].i_RAM_example|s_mem|ram0_0_0_0','CGB[8x8]')”, and relaunch the project.
Check in preplaced.rpt report the constraint matched with the desired instance.
Info |
---|
In case of direct primitive instance of the RAM, RAM name is the path to the RAM. For instance, p.addRAMLocation('module0|submodule1|ram','CGB[28x4]'). |
Please have a look at Training Package Application Note PlacingConstraint/RamLocation project.
...
In order to place manually an automatically created WFG in a CKG spot, follow the following steps:
Launch your design for the first time without constraint.
Grab the RAM name in lowskew.rpt report. For instance, “rg~clk_divp2 from instance wfg_B_clk_divp2”, name is “wfg_B_clk_divp2”.
Add the constraint specifying RAM spot (CGB coordinates), for instance “p.addRingLocation(' wfg_B_clk_divp2','CKG3.WFG_C1')”, and relaunch the project.
Check in preplaced.rpt report the constraint matched with the desired instance.
Info |
---|
In case of direct primitive instance of the WFG or PLL, WFG or PLL name is the path to the WFG or PLL. For instance, p.addRingLocation('module0|submodule1|PLL_INST0','CKG3.PLL1') or p.addRingLocation('module0|submodule1|WFG_INST0','CKG3.WFG_C1'). |
Note |
---|
In order to place manually a WFG, location must comply with WFG type that is to say Core WFG (WFG_Cx) or Ring WFG (WFG_Rx). Mix WFG (WFG_Mx) can be chosen for either a Core or a Ring signal. |
Please have a look at Training Package Application Note PlacingConstraint/RingLocation project.
...
In order to place manually an inferred TILE instance like DFF, LUT or CY, follow the following steps:
Launch your design for the first time without constraint.
Grab the register name in RegisterSummary.rpt report or in timing files. For instance, i_cpt_0|s_cpt_out_reg[5]”.
Add the constraint specifying TILE spot (TILE coordinates), for instance “p.setSite('i_cpt_0|s_cpt_out_reg[0]','TILE[2x2]'”, and relaunch the project.
Check in preplaced.rpt report the constraint matched with the desired instance.
Please have a look at Training Package Application Note PlacingConstraint/Site project.
Floor planning
...
Add the constraint specifying RAM spot (CGB coordinates), for instance “p.addRAMLocation('g_loop[0].i_RAM_example|s_mem|ram0_0_0_0','CGB[8x8]')”, and relaunch the project.
Check in preplaced.rpt report the constraint matched with the desired instance.
Info |
---|
In case of direct primitive instance of the RAM, RAM name is the path to the RAM. For instance, p.addRAMLocation('module0|submodule1|ram','CGB[28x4]'). |
Please have a look at Impulse 23.3 Training Package : Application Note PlacingConstraint/RamLocation project.
Anchor | ||||
---|---|---|---|---|
|
In order to place manually an automatically created WFG in a CKG spot, follow the following steps:
Launch your design for the first time without constraint.
Grab the RAM name in lowskew.rpt report. For instance, “rg~clk_divp2 from instance wfg_B_clk_divp2”, name is “wfg_B_clk_divp2”.
Add the constraint specifying RAM spot (CGB coordinates), for instance “p.addRingLocation(' wfg_B_clk_divp2','CKG3.WFG_C1')”, and relaunch the project.
Check in preplaced.rpt report the constraint matched with the desired instance.
Info |
---|
In case of direct primitive instance of the WFG or PLL, WFG or PLL name is the path to the WFG or PLL. For instance, p.addRingLocation('module0|submodule1|PLL_INST0','CKG3.PLL1') or p.addRingLocation('module0|submodule1|WFG_INST0','CKG3.WFG_C1'). |
Note |
---|
In order to place manually a WFG, location must comply with WFG type that is to say Core WFG (WFG_Cx) or Ring WFG (WFG_Rx). Mix WFG (WFG_Mx) can be chosen for either a Core or a Ring signal. |
Please have a look at Impulse 23.3 Training Package : Application Note PlacingConstraint/RingLocation project.
Anchor | ||||
---|---|---|---|---|
|
In order to place manually an inferred TILE instance like DFF, LUT or CY, follow the following steps:
Launch your design for the first time without constraint.
Grab the module and instance register name in hierarchyRegisterSummary.rpt report or in timing files. For instance, “| |-> timing_pipe(X2A98C8C6) [ GEN_HIER0|GEN_ROW[0].ROW_PIPE ]”, module name is timing_pipe(X2A98C8C6)” and instance name is “[ GEN_HIER0|GEN_ROW[0].ROW_PIPE ] i_cpt_0|s_cpt_out_reg[5]”.
Add the constraint specifying TILE spot (TILE coordinates), for instance “p.addModule('timing_pipe(X2A98C8C6)', 'GEN_HIER0.GEN_ROW[0].ROW_PIPE', 'GEN_HIER0_ROW-%')setSite('i_cpt_0|s_cpt_out_reg[0]','TILE[2x2]'”, and relaunch the project.
Check in hierarchypreplaced.rpt report the constraint matched with the desired instance.
Please have a look at Impulse 23.3 Training Package : Application Note PlacingConstraint/Region Site project.
Floor planning
Anchor | ||||
---|---|---|---|---|
|
In order to confine a module (component of the design hierarchy) in a region containing TILE, CGB and MESH, follow the following steps:
Launch your design for the first time without constraint.
Grab the module name in hierarchy.rpt report. For instance, “| ~ |-> row_col_pipe(X212B9C19) [ GEN_HIER0 ]”, name is “|-> row_col_pipe(X212B9C19) [ GEN_HIER0 ]”.
Add the constraint specifying area coordinates, for instance “p.constrainModule('|-> row_col_pipe(X212B9C19) [ GEN_HIER0 ]','GEN_HIER0_ROW_M','Soft',9,6,2,3,'GEN_HIER0_ROW_R',False)”, and relaunch the project.
Check in hierarchy.rpt report the constraint matched with the desired instance.
Please have a look at Impulse 23.3 Training Package : Application Note PlacingConstraint/Region project.
Anchor | ||||
---|---|---|---|---|
|
In order to confine all instances in a path between 2 registers in a region containing TILE, CGB and MESH, follow the following steps:
Launch your design for the first time without constraint.
Grab the source and target register in DOMAIN_<clk1>_to_<clk2>_<progress_step>_<conditions>.timing. For instance, “module0|submodule0|pipe_reg[0].CK” and “module0|submodule0|pipe_reg[1].CK” , names are “module0|submodule0|pipe_reg[0]” and “module0|submodule0|pipe_reg[1]”.
Add the constraint specifying area coordinates, for instance “p.constrainPath('|-> row_col_pipe(X212B9C19) [ GEN_HIER0 ]','PIPE_REG_M','Soft',9,6,2,3,'PIPE_REG_R',False)”, and relaunch the project.
Check in hierarchy.rpt report the constraint matched with the desired instance.
Please have a look at Impulse 23.3 Training Package : Application Note PlacingConstraint/ConstrainPath project.
Anchor | ||||
---|---|---|---|---|
|
In order to preplace a macro IP of a global design in order to reach design specifications (delays, maximum frequencies, …) in an area of the chip before integrating it in the global design, follow the following steps:
Define the macro IP as the top cell.
Define a minimum aperture and all needed constraints as it was a global project to reach specifications. Save the project file after routed steps.
Run the project until Placing 3/5 step and use saveIP method to save the preplaced IP.
Do not declare the macro IP entity file in the global project. Instead, add the macro IP as a blackbox, specifying coordinates of the top left corner of the macro IP aperture in the global project, for instance “
p.addBlackBox('switch_counter',IP','../switch_counter_preplaced.nymjson','g_inst.i_switch_counter_0:1x8')
”.Check in synthesize.log l log the constraint matched.
Please have a look at Impulse 23.3 Training Package : Application Note PlacingConstraint/Preplace project.
In case of insufficient number of IO in the preplacing IP project, use can use the embedded variant of the same FPGA target.
STA constraints
Anchor | ||||
---|---|---|---|---|
|
In order to declare a clock in your project in order to get required frequencies in logs, follow the following steps:
...
developCKGs method is active by default, NXmap compute Impulse computes automatically PLL and WFG required frequencies if input clock is declared.
Please have a look at Impulse 23.3 Training Package : Application Note StaConstraint/GeneratedClock project.
Anchor | ||||
---|---|---|---|---|
|
In order to declare a clock in your project in order to get required frequencies in logs, follow the following steps:
Grab the clock name getting the hierarchy path to the generated clock.
Add the constraint specifying clock parameters, for instance “p.createGeneratedClock(getClock('clk_main'),getRegisterClock('i_clock_0|counter_reg[0]'), 'clk_fabric',{'DivideBy': 2})”.
Check timing files are created for this new clock domain.
Please have a look at Impulse 23.3 Training Package : Application Note StaConstraint/GeneratedClock project.
Anchor | ||||
---|---|---|---|---|
|
In order to declare a path between 2 registers as a false path, multi-cycle path, min or max delay path, follow the following steps:
Launch your design for the first time without constraint.
Grab the source and target register in DOMAIN_<clk1>_to_<clk2>_<progress_step>_<conditions>.timing. For instance, “module0|submodule0|pipe_reg[0].CK” and “module0|submodule0|pipe_reg[1].CK” , names are “module0|submodule0|pipe_reg[0]” and “module0|submodule0|pipe_reg[1]”.
Add the constraint specifying area coordinates, for instance “p.addFalsePath('getRegisters(module0|submodule0|pipe_reg[0])','getRegisters(module0|submodule0|pipe_reg[0])')”, and relaunch the project.
Check in DOMAIN_<clk1>_to_<clk2>_<progress_step>_<conditions>.timingt report the path no longer appears.
Please have a look at Impulse 23.3 Training Package : Application Note StaConstraint/FalsePath project.
How to improve STA results
STA tool
It is recommended to launch the STA tool after Placing 1/5 step named “Preparing”. It allows to witness the number of logic elements crossed and check if it is possible to reach performances when the margin in the most optimistic scenario is high enough.
ClockCreation
Before launching STA tool, all constraints must be defined.
...
createClock for clock coming from a port. Refer to #Sta_constraints_Clock_creation.
createGeneratedClock if a clock is generated inside the fabric. Refer to #Sta_constraints_Generated_clock_creation.
addFalsePath in order to remove paths to ignore. Refer to #Sta_constraints_Path_between_registers.
TimingDriven
TimingDriven option can be set with the following constraint:
...
The higher the number of iterations is, the higher STA performances can be high but the higher . However, higher is the runtime is.
Note |
---|
All clocks must be created before launching Place&Route with TimingDriven option. Otherwise, the tool does not get performances to reach. |
Note |
---|
The TimingDriven efficiency is in continuous development and improvement. |
Floor planning
In order to give indications to the tool, the user can set up a floor-planning and pass it through the tool working directly on the whole design or working with unitary runs before integrating in the top design as specified in #Floor_planning_Preplace_ip.
First of all, ConstrainModule methods method as explained in #Floor_planning_Constrain_module must be applied in order to concentrate parts of the design and place them close to other ones if there are interconnections between them.
In addition, ConstraintPath methods method as explained in #Floor_planning_Constrain_path_between_registers must be applied if some path paths go trough multiple modules or for last critical paths.
Note |
---|
With this solution, the user must pay attention to interconnections between modules and between module and output interfacesmodules and the ring device. |
Logic depth reducing